Mouse Transforming Growth Factor β1 (TGF-β1) ELISA Kit Instructions

Experimental principle of mouse ELISA kit This kit uses the double antibody sandwich method to determine the level of mouse transforming growth factor β1 (TGF-β1) in the specimen. Microporous plates were coated with purified mouse transforming growth factor β1 (TGF-β1) antibody to prepare solid-phase antibodies. Transforming growth factor β1 (TGF-β1) was added to the monoclonal antibody-coated microwells in turn, followed by HRP The labeled transforming growth factor β1 (TGF-β1) antibody binds to form an antibody-antigen-enzyme-labeled antibody complex. After thorough washing, the substrate TMB is added for color development. TMB is converted into blue under the catalysis of HRP enzyme, and into the final yellow under the action of acid. The color depth is positively correlated with transforming growth factor β1 (TGF-β1) in the sample. The absorbance (OD value) was measured with a microplate reader at a wavelength of 450 nm, and the concentration of mouse transforming growth factor β1 (TGF-β1) in the sample was calculated by a standard curve. Kit composition 130 times concentrated washing solution 20ml × 1 bottle 7 stop solution 6ml × 1 bottle 2 enzyme label reagent 6ml × 1 bottle 8 standard (240pg / ml) 0.5ml × 1 bottle 3 enzyme label coated plate 12 well × 8 Strip 9 Standard diluent 1.5ml × 1 bottle 4 Sample diluent 6ml × 1 bottle 10 Instructions 1 copy 5 developer A solution 6ml × 1 bottle 11 sealing film 2 sheets 6 developer B solution 6ml × 1 / bottle 12 Sealed bag 1 specimen requirement 1. Specimens are extracted as soon as possible after collection, and extraction is performed according to relevant literature, and experiments should be conducted as soon as possible after extraction. If the test cannot be performed immediately, the specimen can be stored at -20 ℃, but repeated freezing and thawing should be avoided. The samples containing NaN3 cannot be detected because NaN3 inhibits horseradish peroxidase (HRP) activity. Operation Steps of Mouse ELISA Kit 1. Dilution of Standards: This kit provides one original standard. The user can perform dilution in a small test tube according to the following chart. 120pg / ml No. 5 standard 150μl original standard added 150μl standard dilution 60pg / ml No. 4 standard 150μl No. 5 standard added 150μl standard No. 5 dilution 30pg / ml No. 3 standard 150μl No. 4 standard added 150μl Standard Diluent 15pg / ml No. 2 Standard 150μl No. 3 Standard Add 150μl Standard Dilute 7.5pg / ml No. 1 Standard 150μl No. 2 Standard Add 150μl Standard Dilute 2. Add Samples: Set Blank Wells (Blank control wells do not add samples and enzyme-labeled reagents, the remaining steps are the same), standard wells, sample wells to be tested. Accurately add 50μl of the standard on the enzyme-coated plate, add 40μl of sample diluent to the sample well, and then add 10μl of the sample to be tested (the final dilution of the sample is 5 times). Add the sample and add the sample to the bottom of the well of the microplate, try not to touch the wall of the well, shake gently to mix. 3. Incubation: Seal the plate with a sealing plate and incubate at 37 ° C for 30 minutes. 4. Mixing solution: Dilute the 30-fold concentrated washing solution with distilled water 30-fold and reserve for use. 5. Washing: Carefully remove the sealing film, discard the liquid, spin dry, fill each well with the washing solution, and let it stand for 30 seconds before discarding , Repeat this 5 times, pat dry. 6. Add enzyme: add 50μl of enzyme label reagent to each well, except blank well. 7. Incubation: The operation is the same as 3. 8. Washing: The operation is the same as 5. 9. Color development: add 50μl of developer A to each well, then add 50μl of developer B, mix gently, and develop color at 37 ° C in the dark 15 minutes. 10. Stop: Add 50μl of stop solution to each well to stop the reaction (the blue color turns to yellow at this time). 11. Determination: Measure the absorbance (OD value) of each well in sequence with the blank air conditioner at zero and 450 nm wavelength. The measurement should be carried out within 15 minutes after adding the stop solution. Summary of operating procedures: Calculate the concentration of the standard as the abscissa and the OD as the ordinate, draw a standard curve on the graph paper, and find the corresponding concentration from the standard curve according to the OD value of the sample; then multiply by the dilution factor; Calculate the linear regression equation of the standard curve using the concentration and OD value of the standard, substitute the OD value of the sample into the equation, calculate the sample concentration, and multiply it by the dilution factor to obtain the actual concentration of the sample. Matters needing attention 1. The kit should be equilibrated at room temperature for 15-30 minutes before being taken out of the refrigerated environment. If the enzyme label coated plate is unopened, the strip should be stored in a sealed bag. 2. Crystals may be precipitated in the concentrated washing liquid, which can be heated and dissolved in a water bath during dilution, and the results will not be affected during washing. 3. The sampler should be used at each step of sample addition, and the accuracy should be regularly checked to avoid test errors. It is best to control the sampling time within 5 minutes. If there are many specimens, it is recommended to use a volley gun to add samples. 4. Please make a standard curve at the same time of each measurement, it is best to make a double hole. If the content of the test substance in the specimen is too high (the OD value of the sample is greater than the OD value of the first well of the standard well), please first dilute it with a certain multiple (n times) of the sample diluent and then determine it. When calculating, please multiply the total dilution Multiple (× n × 5). 5. The sealing film is limited to one-time use to avoid cross-contamination. 6. Please keep the substrate away from light. 7. Strictly follow the instructions, and the test results must be determined based on the reading of the microplate reader. 8. All samples, washing liquids and various wastes should be treated as infectious agents. 9. The components of different batches of this reagent shall not be mixed. 10. If there is any difference with the English manual, the English manual shall prevail. Storage conditions and expiration date of mouse ELISA kit Kit storage :; 2-8 ℃. 2. Validity: 6 months

Office Desk

1. Workstation: A must-have in a classic office environment. Modular and expandable workstation design can effectively help you plan your office environment. Modular design reduces various types of communication between office areas, saves time spent on mobility, and improves office efficiency.Multiple combinations according to your heart, meeting all your needs for the office environment.


2. CEO desk: A spacious desktop that effectively stores various required office files and allows you to plan your own desktop usage space. Front bezel design helps protect your security and privacy.


3. Boss desk: As the leader in the office. His desk is spacious and stylish, suitable for any office environment. Modern classic design allows you to strategize within the office and win thousands of miles away.


4. Computer desk: Modern offices are equipped with a computer, so a computer desk has emerged. A high-quality material desktop can support your computer well.


Isn't a high-quality desk appealing to you? It can be suitable for your office and take your work environment to the next level.

Workstation,Ceo Desk,Boss Desk,Computer Table

Foshan Shengshi Zhihui Technology Co., Ltd. , https://www.officer-furniture.com