Kit instruction manual
This reagent is for research purpose only: this kit is used to determine the content of β2-glycoprotein 1 antibody IgG (β2-GP1 IgG) in human serum, plasma and related liquid samples.
Experimental principle:
This kit uses the double antigen sandwich method to determine the level of human β2 glycoprotein 1 antibody IgG (β2-GP1 IgG) in the specimen. The microplate is coated with purified antigen to prepare a solid-phase antigen, and the β2 glycoprotein 1 antibody IgG (β2-GP1 IgG) is added to the monoclonal antibody-coated microwells in sequence, and then combined with the HRP-labeled antigen to form an antigen Antibody-enzyme labeled antigen complex, after thorough washing, add substrate TMB to develop color. TMB is converted into blue under the catalysis of HRP enzyme, and into the final yellow under the action of acid. The color depth is positively correlated with the β2-glycoprotein 1 antibody IgG (β2-GP1 IgG) in the sample. The absorbance (OD value) was measured with a microplate reader at a wavelength of 450 nm, and the concentration of human β2 glycoprotein 1 antibody IgG (β2-GP1 IgG) in the sample was calculated by a standard curve.
Kit composition:
Kit composition
48 hole configuration
96-well configuration
save
Instructions
1 serving
1 serving
Sealing film
2 pieces (48)
2 pieces (96)
sealed bag
1
1
Enzyme coated plate
1 × 48
1 × 96
Store at 2-8 ℃
Standard product: 1080μg / L
0.5ml × 1 bottle
0.5ml × 1 bottle
Store at 2-8 ℃
Standard dilution
1.5ml × 1 bottle
1.5ml × 1 bottle
Store at 2-8 ℃
Enzyme reagent
3 ml × 1 bottle
6 ml × 1 bottle
Store at 2-8 ℃
Sample diluent
3 ml × 1 bottle
6 ml × 1 bottle
Store at 2-8 ℃
Developer A liquid
3 ml × 1 bottle
6 ml × 1 bottle
Store at 2-8 ℃
Developer B liquid
3 ml × 1 bottle
6 ml × 1 bottle
Store at 2-8 ℃
Stop solution
3ml × 1 bottle
6ml × 1 bottle
Store at 2-8 ℃
20 times concentrated washing liquid
20ml × 1 bottle
23ml × 1 bottle
Store at 2-8 ℃
Sample processing and requirements:
1. Serum: room temperature blood coagulates naturally for 10-20 minutes, centrifuged for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully and centrifuge again if a precipitate appears during storage.
2. Plasma: EDTA or sodium citrate should be selected as the anticoagulant according to the requirements of the specimen, mixed for 10-20 minutes, and centrifuged for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. If a precipitate forms during storage, it should be centrifuged again.
3. Urine: collected in a sterile tube and centrifuged for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. If a precipitate forms during storage, centrifuge again. Pleural and ascites, cerebrospinal fluid reference implementation.
4. Cell culture supernatant: When detecting secreted components, collect with a sterile tube. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. When detecting the components inside the cells, dilute the cell suspension with PBS (PH7.2-7.4), and the cell concentration will reach about 1 million / ml. Through repeated freezing and thawing, the cells are destroyed and the intracellular components are released. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. If a precipitate forms during storage, it should be centrifuged again.
5. Organize the specimen: after cutting the specimen, weigh it. Add a certain amount of PBS, PH7.4. Quickly freeze and save with liquid nitrogen for later use. After the specimen melts, it still maintains a temperature of 2-8 ° C. Add a certain amount of PBS (PH7.4) and homogenize the specimen with a manual or homogenizer. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. After aliquoting, a portion is to be tested, and the rest is frozen for future use.
6. The specimen should be extracted as soon as possible after collection. The extraction should be carried out according to relevant literature. The experiment should be carried out as soon as possible after extraction. If the test cannot be performed immediately, the specimen can be stored at -20 ℃, but repeated freezing and thawing should be avoided.
7. The sample containing NaN3 cannot be detected because NaN3 inhibits the activity of horseradish peroxidase (HRP).
Steps
1. Dilution and loading of standard products: set 10 standard wells on the enzyme-coated plate, add 100 μl of standard products in the first and second wells, and then add standard products in the first and second wells 50μl of diluent, mix well; then take 100μl from the first well and the second well and add them to the third and fourth wells respectively, and then add 50μl of standard diluent to the third and fourth wells respectively, mix well; Then take 50μl each in the third and fourth wells and discard it, then add 50μl each to the fifth and sixth wells, and then add 50ul of the standard dilution solution to the fifth and sixth wells respectively, and mix well; After mixing, take 50μl from the fifth and sixth wells and add them to the seventh and eighth wells respectively. Then add 50μl of the standard dilution solution to the seventh and eighth wells respectively. Take 50μl from the eight wells and add them to the ninth and tenth wells. Then add 50μl of the standard dilution solution to the ninth and tenth wells. After mixing, take 50μl from the ninth and tenth wells and discard. (After dilution, the volume of each well is 50μl, and the concentration is 720μg / L, 480μg / L, 240μg / L, 120μg / L, 60μg / L).
2. Add samples: set up blank wells (the blank control wells do not add samples and enzyme reagents, the rest of the steps are the same) and the sample wells to be tested. Add 40μl of sample diluent to the test sample well of the enzyme-coated plate, and then add 10μl of the sample to be tested (the final dilution of the sample is 5 times). Add the sample and add the sample to the bottom of the well of the microplate, try not to touch the wall of the well, shake gently to mix.
3. Incubation: Seal the plate with a sealing plate and incubate at 37 ° C for 30 minutes.
4. Mixing solution: dilute 20 times concentrated washing liquid with distilled water 20 times and reserve.
5. Washing: Carefully peel off the sealing film, discard the liquid, spin dry, fill each well with the washing liquid, let it stand for 30 seconds and then discard, repeat this 5 times, pat dry.
6. Add enzyme: add 50μl of enzyme label reagent to each well, except blank well.
7. Incubation: The operation is the same as 3.
8. Washing: The operation is the same as 5.
9. Color development: add 50μl of developer A to each well, then add 50μl of developer B, mix gently, and develop at 37 ° C in the dark for 15 minutes.
10. Termination: Add 50μl of stop solution to each well to stop the reaction (at this time the blue will turn to yellow).
11. Determination: Measure the absorbance (OD value) of each well in sequence with the blank air conditioner at zero and 450 nm wavelength. The measurement should be carried out within 15 minutes after adding the stop solution.
Precautions:
1. The kit should be equilibrated at room temperature for 15-30 minutes before being taken out of the refrigerated environment. If the enzyme label coated plate is unopened, the strip should be stored in a sealed bag.
2. Crystals may be precipitated in the concentrated washing liquid, which can be heated and dissolved in a water bath during dilution, and the results will not be affected during washing.
3. The sampler should be used at each step of sample addition, and the accuracy should be regularly checked to avoid test errors. It is best to control the sampling time within 5 minutes. If there are many specimens, it is recommended to use a volley gun to add samples.
4. Please make a standard curve at the same time of each measurement, it is best to make a double hole. If the content of the test substance in the specimen is too high (the OD value of the sample is greater than the OD value of the first well of the standard well), please first dilute it with a certain multiple (n times) of the sample diluent and then determine it. When calculating, please multiply the total dilution Multiple (× n × 5).
5. The sealing film is limited to one-time use to avoid cross-contamination.
6. Please keep the substrate away from light.
7. Strictly follow the instructions, and the test results must be determined by the microplate reader.
8. All samples, washing liquids and various wastes should be treated as infectious agents.
9. The components of different batches of this reagent shall not be mixed.
10. If there is any difference with the English manual, the English manual shall prevail.
Calculation:
Taking the concentration of the standard as the abscissa and the OD value as the ordinate,
Draw a standard curve on coordinate paper, according to the OD of the sample
The value is determined by the standard curve; then multiplied by the dilution
Multiple; or calculate the standard using the concentration and OD value of the standard
The linear regression equation of the quasi-curve, the OD value of the sample
Substitute into the equation, calculate the sample concentration, and multiply by the dilution
The multiple is the actual concentration of the sample.
(This picture is for reference only)
Kit performance:
1. The correlation coefficient R between the linear regression of the sample and the expected concentration is more than 0.990.
2. The batch and approval shall be less than 9% and 11% respectively
examination range:
30μg / L -900μg / L
Storage conditions and validity period:
1. Store the kit: 2-8 ℃.
2. Validity: 6 months
1.Hinges
The role of the hinge is to connect the cabinet and the door panel, in eating at the same time it is still alone to bear the weight of the door panel, keep the door arrangement with consistency. For hinges, cheap or try not to buy, it is not like a washbasin can say change, good hinges not only long life, installation is also more convenient.
2.Slide rail
If the hinge is the heart of the cabinet, slide rail is equivalent to the kidneys. Large and small drawers can be free to push and pull, depends on the slide rail. Slide rail has roller, steel ball, gear three kinds of classification.
3, damping
Damping is mainly with the slide and hinges, has two important roles, one is to prevent shock absorption, the second is to enhance the accuracy of hardware. Damping hinge is a kind of hinge, can also be called hydraulic hinge. It can close the cabinet in a certain zone by itself, even if the force to close the door, can also slow down the speed to close the cabinet.
4.Hanging code
Hanging code is a small hardware accessory that can be hung on the wall, it can realize the link between the hanging cabinet and the wall. General steel invisible hanging code is stronger, aging cycle is relatively long.
5.Pull-out basket
Pull the basket do not have to choose too much or too high-tech, generally one or two on it, all depending on their own use of happy can be.
6, faucet
Faucet is an essential hardware item in each of our homes. Faucet good or bad, there are more critical five points, material, spool, bubbler, plating, water inlet hose.
Copper is currently a better material in the manufacture of faucets, also called brass.
Spool cost in 4 ~ 20 yuan are available, the more commonly used spool cost generally between 5 ~ 15;.
Bubbler is mainly installed in the spigot's water outlet end, the device that mixes and air when the water comes out. This class increases the flushing force of the water to achieve water conservation.
electroplating can enhance the corrosion resistance and wear resistance of the faucet and improve the aesthetics.
Intake hose is mainly connected at the corner valve and faucet, belonging to the class of accessories, while the hose and not resistant to high pressure and high temperature, long-term water pressure when the hose connector will come out, all in looking at the hose, the hose pipe and joint need to pay special attention to a little.
7.Water basin
Basin material can be divided into stainless steel, artificial stone, ceramic three categories. Currently used in our kitchen, mainly stainless steel. Stainless steel material has light, environmentally friendly, durable, corrosion-resistant features, the style is also more.
8.Drawers
When choosing a drawer, the general standard size control in 30cm-100cm best, 30cm-70cm is a small drawer
Kitchen Hardware,Kitchen Metal Hardware,Water Faucet,Kitchen Hardware Accessory, Kitchen Wasserbecken
OYEAL Global , https://www.oyealhome.com